Add to Cart
20kva Three Phase 380v To 220v Step Down Audio Transformer Ac To Dc 12V 24V 48V Small Electrical Transformer
EI14 transformer introduction
EI14 transformer, low height, small size, can be customized, nickel steel sheet or silicon steel Suitable for usb external soundcard, audio isolation cable, audio converter, etc. Filter noise, sound quality and noise reduction, improve sound quality and make the sound clearer.
Classification
1. Classified by working frequency:
Power frequency (low frequency) transformer, its working frequency is 50HZ or 60HZ;
Intermediate frequency transformer, its working frequency is 400~1000HZ;
Audio transformer, its working frequency is 20HZ~20KHZ
Super audio transformer, its working frequency is above 20KHZ, generally not more than 100KHZ
High frequency transformer, its working frequency is above 20HZ~100KHZ.
2. Classification by use:
Power transformers, audio transformers, pulse transformers, switching power transformers, special transformers
3. According to the iron core structure classification:
Shell-type transformers, such as EI type insert core transformers, F type;
Core-type transformers, such as R-type transformers;
Toroidal Transformer.
4. According to the number of phases:
Single-phase transformers, three-phase transformers, multi-cabin transformers.
5. According to the moisture-proof method:
Open transformers, sealed transformers, resin-encapsulated transformers.
6. Other ways to classify:
For example, according to the transformer coefficient, it can be boosted and stepped down; according to the number of groups, it can be divided into double-winding and multi-winding; according to the insulation level, it can be divided into A-class insulation transformers, E-class insulation transformers, B-class insulation transformers, and F-class insulation transformers. Transformers, H-class insulation transformers, etc.
GENREAL SPECIFICATION:
PATRNUMBER: EI19 soft feet 2+3
STORAGE TEMP RANGE: -45℃ TO +125℃
OPERATING TEMP RANGE: -40℃ TO +85℃
RELATIVE HUMITY RANGE: 5% TO 95%
Specification | Input voltage | frequency | Primary temperature protection | Power range | Windings | Voltage range | No-load voltage | Output current range for single or multiple secondary windings |
EI35 | 220~230V | 50~60Hz | A2-2A-115℃ | ≤5W | <4 | 3V~46V | Sum of secondary voltages<50Vac | 0.1A~2A |
EI41 | 220~230V | 50~60Hz | A2-2A-115℃ | ≤10W | <4 | 3V~46V | 0.1A~4A | |
EI48 | 220~230V | 50~60Hz | A2-2A-115℃ | ≤25W | <4 | 3V~48V | 0.1A~8A | |
EI57 | 220~230V | 50~60Hz | A2-2A-115℃ | ≤40W | <5 | 3V~48V | 0.1A~10A | |
EI66 | 220~230V | 50~60Hz | A4-3A-130℃ | ≤60W | <6 | 5V~48V | 0.1A~10A | |
EI76 | 220~230V | 50~60Hz | A4-3A-130℃ | ≤90W | <6 | 5V~48V | 0.2A~15A | |
EI86 | 220~230V | 50~60Hz | A4-3A-130℃ | ≤120W | <6 | 5V~48V | 0.2A~20A | |
EI96 | 220~230V | 50~60Hz | A4-5A-130℃ | ≤200W | <6 | 5V~48V | 0.1A~30A | |
EI114 | 220~230V | 50~60Hz | A4-5A-130℃ | ≤300W | <6 | 6V~48V | 0.1A~40A | |
EI152 | 220~230V | 50~60Hz | A4-5A-130℃ | ≤900W | <6 | 6V~48V | 0.1A~50A |